I have created sample DAG, where I had DAG config as below. default_args = { 'owner': 'airflow', 'depends_on_past': False, 'start_date': one_min_ago, 'ema
Solution 1:
Those messages are expected. The ttou
(and ttin
) signals are used to refresh gunicorn workers of the webserver so that it picks up DAG changes. You can modify or disable this behavior with the worker_refresh_interval
and worker_refresh_batch_size
airflow config values.
Solution 2:
I don't really want to change worker_refresh_interval
or worker_refresh_batch_size
without a good reason. An alternative is to set an environment variable:
GUNICORN_CMD_ARGS="--log-level WARNING"
If setting this in a docker-compose.yml
file, the following is tested with apache-airflow==1.10.6 with gunicorn==19.9.0:
environment:
- 'GUNICORN_CMD_ARGS=--log-level WARNING'
If setting this in a Dockerfile
, the following is tested with apache-airflow==1.10.6 with gunicorn==19.9.0:
ENV GUNICORN_CMD_ARGS --log-level WARNING
Credit: answer by amoskaliov